Should you need to downgrade from 1.3.x or later to 1.2.2, the originally release files will not work and one must use files with an added CRC.
Follow the normal upgrade procedure, but use the attached files to downgrade if necessary.
Below is a CLI output of the process (assuming TFTPd is already enabled and the files have been transferred to the Apex).
FPGA version: 0015070A OS version: 2p6r14b0D111910 FW version: 1p3r1D111910 PIC version: 217 Modem version: 40 RFM version: 28 Previous Image Version: FPGA version: 0015070A OS version: 2p6r14b0D111910 FW version: 1p3r1D111910 PIC version: 217 RFM version: 28
(trango-config)# bootimage upgrade 0 . . . SUCCESS (trango-config)# bootimage upgrade 1 . . . . . . . . . . . . . . . . SUCCESS (trango-config)# bootimage upgrade 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SUCCESS (trango-config)#
Trango System: TrangoLINK Apex Command Line Interface v1.2.2 (trango-config)# version Current Image Version FPGA version: 00080809 OS version: 2p6r14b3D08200901 FW version: 1p2r2D082009 PIC version: 217 Modem version: 38 RFM version: 28 Previous Image Version: FPGA version: 0015070A OS version: 2p6r14b0D111910 FW version: 1p3r1D111910 PIC version: 217 RFM version: 28