Technical Advisory Bulletin: |
TAB-11-0004 |
Equipment: |
TrangoLINK® Apex |
Condition: |
Upgrading firmware may result in loss of calibration data. |
Description: |
Some users have experienced the loss of calibration data when upgrading Apex firmware. To prevent this, a new procedure for performing a firmware upgrade has been released. Does not affect ApexPlus, GigaPlus or GigaPro products. |
Solution:
|
Instead of upgrading all images in one step, it is suggested for a two- or three-step process:
It should be possible to continue to use the link (in-band) to transfer the files and manage the far side radio, however, best practice would call for out of band access to the remote radio in case the link cannot be re-established during the firmware upgrade process. For detailed upgrade instructions, including TFTP instructions to copy the files to the radio for each step, please consult the release notes. If you have a unit that you suspect has lost calibration data, please contact Trango Technical Support for assistance in restoring the calibration data. |