Please find attachment for Apexplus console cable Pin-outs or check page no:165 on ApexPlus user manual Rev 1.0.
Connect Serial/Console cable to Trango Apex at one end and reboot the radio with below Serial/Console port settings on your laptop/computer at other end.
Serial Port Settings:
Bits per second: 115200
Data bits: 8
Parity: None
Stop Bits: 1
Flow Control: none
You will be prompted with trango login: prompt.
Login with Default username: admin password: trango
You need to login to config mode to change configuration. Simply type config in view mode and password: trango