GIGA-PLUS-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY, IpAddress, Unsigned32, Counter64, NOTIFICATION-TYPE, enterprises FROM SNMPv2-SMI MODULE-COMPLIANCE FROM SNMPv2-CONF DisplayString FROM SNMPv2-TC; -- ******************************************************************* -- * Trango module -- ******************************************************************* trango OBJECT IDENTIFIER ::= { enterprises 5454 } tbw OBJECT IDENTIFIER ::= { trango 1 } ptp OBJECT IDENTIFIER ::= { tbw 80 } sys OBJECT IDENTIFIER ::= { ptp 1 } modem OBJECT IDENTIFIER ::= { ptp 2 } rf OBJECT IDENTIFIER ::= { ptp 3 } gige OBJECT IDENTIFIER ::= { ptp 4 } tdm OBJECT IDENTIFIER ::= { ptp 5 } trangotrap OBJECT IDENTIFIER ::= { ptp 6 } -- ******************************************************************* -- ** System Information ** trango.tbw.ptp.sys -- ******************************************************************* community OBJECT IDENTIFIER ::= { sys 8 } sysSNMPReadCommStr OBJECT-TYPE SYNTAX DisplayString (SIZE(1..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP agent read community string" ::= { community 1 } sysSNMPWriteCommStr OBJECT-TYPE SYNTAX DisplayString (SIZE(1..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP agent Write community string" ::= { community 2 } sysSNMPTrapCommStr OBJECT-TYPE SYNTAX DisplayString (SIZE(1..32)) MAX-ACCESS read-write STATUS current DESCRIPTION "SNMP trap community string" ::= { community 3 } sysIDUTemp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "PIC's current temperatur reading in Celsius" ::= { sys 19 } sysVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Display system voltage" ::= { sys 44 } sysUptime OBJECT-TYPE SYNTAX DisplayString (SIZE(1..100)) MAX-ACCESS read-only STATUS current DESCRIPTION "Display system uptime" ::= { sys 45 } sysVoltage12 OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Display power input(1.2V) " ::= { sys 49 } sysVoltage25 OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Display power input(2.5V)" ::= { sys 50 } sysVoltage33 OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Display power input(3.3V)" ::= { sys 51 } acm OBJECT IDENTIFIER ::= { modem 3 } profile_x OBJECT IDENTIFIER ::= { acm 5} modemACMTxProfile OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Display ACM transmitter profile" ::= { profile_x 1 } modemACM256RxProfile OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Display ACM receiver profile" ::= { profile_x 2 } link OBJECT IDENTIFIER ::= { modem 4 } link_ber OBJECT IDENTIFIER ::= { link 1 } modemBER OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Set/Display BER value" ::= { link_ber 1 } modemBERStr OBJECT-TYPE SYNTAX DisplayString (SIZE(0..80)) MAX-ACCESS read-only STATUS current DESCRIPTION "Display BER value string" ::= { link_ber 2 } mse OBJECT IDENTIFIER ::= { link 2 } modemMSE OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Display MSE value" ::= { mse 1 } modemMSEInt OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Display MSE value" ::= { mse 2 } lock OBJECT IDENTIFIER ::= { modem 5 } modemLockStatus OBJECT-TYPE SYNTAX INTEGER { nolock(0), lock(1), NA(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Set/Display link lock statsu" ::= { lock 1 } debug OBJECT IDENTIFIER ::= { modem 6 } modemLDPCStressDecoder OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Display LDPC Stress Decoder" ::= { debug 1 } hc OBJECT IDENTIFIER ::= { modem 8 } modemHCNetComp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Display HC net compression" ::= { hc 4 } modemHCGrossComp OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Display HC gross compression" ::= { hc 5 } modemTxCapacity OBJECT-TYPE SYNTAX OPAQUE(Float) MAX-ACCESS read-only STATUS current DESCRIPTION "Display transmitter capacity" ::= { modem 10 } modemSpeedCurrent OBJECT-TYPE SYNTAX OPAQUE(Float) MAX-ACCESS read-only STATUS current DESCRIPTION "Display current speed" ::= { modem 11 } power OBJECT IDENTIFIER ::= { rf 4 } rfPower OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "Set/Display TX power. SNMPc does not support setting and displaying float value." ::= { power 1 } rfPowerInt OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Set/Display TX power 1/10 dB in step size " ::= { power 2 } rssi OBJECT IDENTIFIER ::= { rf 14 } rfRSSIInt OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-only STATUS current DESCRIPTION "Display current RSSI value " ::= { rssi 2 } pll OBJECT IDENTIFIER ::= { rf 15 } rfODUIFpll OBJECT-TYPE SYNTAX INTEGER { nolock(0), lock(1), NA(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Display current status of ODU IF PLL " ::= { pll 2 } rfODUTxpll OBJECT-TYPE SYNTAX INTEGER { nolock(0), lock(1), NA(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Display current status of ODU TX PLL " ::= { pll 3 } rfODURxpll OBJECT-TYPE SYNTAX INTEGER { nolock(0), lock(1), NA(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Display current status of ODU RX PLL " ::= { pll 4 } rfIDUTxpll OBJECT-TYPE SYNTAX INTEGER { nolock(0), lock(1), NA(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Display current status of IDU TX PLL " ::= { pll 5 } eth1 OBJECT IDENTIFIER ::= { gige 1 } config1 OBJECT IDENTIFIER ::= { eth1 1 } gigeEth1Speed OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Set/Display speed setting for ETH 1" ::= { config1 7 } gigeEth1Status OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Set/Display port status for ETH 1" ::= { config1 8 } counter1 OBJECT IDENTIFIER ::= { eth1 2 } gigeEth1InTotalPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH1 IN non-unicast packet counter" ::= { counter1 4 } gigeEth1OutTotalPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH1 OUT total packet counter" ::= { counter1 8 } gigeEth1CRCError OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH1 CRC error counter" ::= { counter1 9 } gigeEth1CollisionError OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH1 Collision error counter" ::= { counter1 10 } gigeEth1InPortRate OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH1 In Port Rate" ::= { counter1 11 } gigeEth1InPortUtil OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH1 In Port utilization" ::= { counter1 12 } gigeEth1OutPortRate OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH1 Out Port Rate" ::= { counter1 13 } gigeEth1OutPortUtil OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH1 Out Port utilization" ::= { counter1 14 } gigeEth1InDiscard OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display Eth1 In Discard" ::= { counter1 15 } gigeEth1OutDiscard OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display Eth1 Out Discard" ::= { counter1 16 } eth2 OBJECT IDENTIFIER ::= { gige 2 } config2 OBJECT IDENTIFIER ::= { eth2 1 } gigeEth2Speed OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Set/Display speed setting for ETH 2" ::= { config2 7 } gigeEth2Status OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Set/Display port status for ETH 2" ::= { config2 8 } counter2 OBJECT IDENTIFIER ::= { eth2 2 } gigeEth2InTotalPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH2 IN non-unicast packet counter" ::= { counter2 4 } gigeEth2OutTotalPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH2 OUT total packet counter" ::= { counter2 8 } gigeEth2CRCError OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH2 CRC error counter" ::= { counter2 9 } gigeEth2CollisionError OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH2 Collision error counter" ::= { counter2 10 } gigeEth2InPortRate OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH2 In Port Rate" ::= { counter2 11 } gigeEth2InPortUtil OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH2 In Port utilization" ::= { counter2 12 } gigeEth2OutPortRate OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH2 Out Port Rate" ::= { counter2 13 } gigeEth2OutPortUtil OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH2 Out Port utilization" ::= { counter2 14 } gigeEth2InDiscard OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display Eth2 In Discard" ::= { counter2 15 } gigeEth2OutDiscard OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display Eth2 Out Discard" ::= { counter2 16 } eth3 OBJECT IDENTIFIER ::= { gige 3 } config3 OBJECT IDENTIFIER ::= { eth3 1 } gigeEth3Speed OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Set/Display speed setting for ETH 3" ::= { config3 7 } gigeEth3Status OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Set/Display port status for ETH 3" ::= { config3 8 } counter3 OBJECT IDENTIFIER ::= { eth3 2 } gigeEth3InTotalPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH3 IN non-unicast packet counter" ::= { counter3 4 } gigeEth3OutTotalPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH3 OUT total packet counter" ::= { counter3 8 } gigeEth3CRCError OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH3 CRC error counter" ::= { counter3 9 } gigeEth3CollisionError OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH3 Collision error counter" ::= { counter3 10 } gigeEth3InPortRate OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH3 In Port Rate" ::= { counter3 11 } gigeEth3InPortUtil OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH3 In Port utilization" ::= { counter3 12 } gigeEth3OutPortRate OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH3 Out Port Rate" ::= { counter3 13 } gigeEth3OutPortUtil OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH3 Out Port utilization" ::= { counter3 14 } gigeEth3InDiscard OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display Eth3 In Discard" ::= { counter3 15 } gigeEth3OutDiscard OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display Eth3 Out Discard" ::= { counter3 16 } eth4 OBJECT IDENTIFIER ::= { gige 4 } config4 OBJECT IDENTIFIER ::= { eth4 1 } gigeEth4Speed OBJECT-TYPE SYNTAX INTEGER MAX-ACCESS read-write STATUS current DESCRIPTION "Set/Display speed setting for ETH 4" ::= { config4 7 } gigeEth4Status OBJECT-TYPE SYNTAX INTEGER { off(0), on(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Set/Display port status for ETH 4" ::= { config4 8 } counter4 OBJECT IDENTIFIER ::= { eth4 2 } gigeEth4InTotalPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH3 IN non-unicast packet counter" ::= { counter4 4 } gigeEth4OutTotalPackets OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH3 OUT total packet counter" ::= { counter4 8 } gigeEth4CRCError OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH3 CRC error counter" ::= { counter4 9 } gigeEth4CollisionError OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH3 Collision error counter" ::= { counter4 10 } gigeEth4InPortRate OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH3 In Port Rate" ::= { counter4 11 } gigeEth4InPortUtil OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display ETH3 In Port utilization" ::= { counter4 12 } gigeEth4OutPortRate OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display Eth4 Out Port Rate" ::= { counter4 13 } gigeEth4OutPortUtil OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display Eth4 Out Port utilization" ::= { counter4 14 } gigeEth4InDiscard OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display Eth4 In Discard" ::= { counter4 15 } gigeEth4OutDiscard OBJECT-TYPE SYNTAX Integer MAX-ACCESS read-only STATUS current DESCRIPTION "Display Eth4 Out Discard" ::= { counter4 16 } END